COMMAND DETAILS
159
GLOBal Subsystem
:GLOBal:CONFigure:VOLTage:RANGe ..................... 159
:GLOBal:LOAD:SHORt ................................................ 159
:GLOBal:MODE ............................................................ 159
:GLOBal:CONFigure:VOLTage:RANGe
Global Command
Description
Sets the CC Voltage range high or low. This
command applies to all channels.
Syntax
:GLOBal:CONFigure:VOLTage:RANGe {L|H}
Parameter
L
Low range
H
High range
Example
:GLOB:CONF:VOLT:RANG L
Sets the range to low.
:GLOBal:LOAD:SHORt
Global Command
Description
Shorts all the input terminals.
Syntax
:GLOBal:LOAD:SHORt {OFF|0|ON|1}
Parameter
{OFF|0|ON|1}
SHORT
OFF/0
Off
ON/1
On
Example
:GLOB:LOAD:SHOR 0
Short on.
Query Syntax
:GLOBal:LOAD:SHORt?
:GLOBal:MODE
Global Command
Description
Sets the mode for all the load modules in the
mainframe.