Gw-instek PEL-2000 Series Programming User Manual Instrukcja Użytkownika Strona 152

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 170
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 151
PEL-2000 Programming Manual
152
1.2
1.2A/us
1.2 A/us
1.2A/us
MAX/MIN
Maximum or minimum
value.
Example
:SEQ:POIN:RISE .3 A
Sets the rising slew rate
to 0.3 A/us
:SEQ:POIN:FALL .4 A
Sets the falling slew rate
to 0.4 A/us
Query Syntax
:SEQuence:POINt::RISE/FALL? [MAX|MIN]
Return Parameter
<NR1>
Slew Rate
1 unit = 1 A/us
Returns the slew rate.
MAX/MIN
Returns the allowable
maximum and minimum.
Query Example
:SEQ:POIN:RISE?
0.30000
Returns the rising slew
rate (0.3 A/us).
:SEQ:POIN:FALL?
0.40000
Returns the falling slew
rate (0.4 A/us).
:SEQuence:POINt:TIME
Channel Specific
Command
Description
Sets the duration time of the current point in
seconds.
Syntax
:SEQuence:POINt:TIME <NRf>[S]|MIN|MAX
Parameter
<NRf>
Duration Time
0.0001~60000
0.0001~60,000.0 seconds
0.0001~60000S
0.0001~60,000.0 seconds
MIN
0.0001seconds
MAX
60,000 seconds
Example
:SEQ:POIN:TIME 10
Sets the point duration
time to 10 seconds.
Query Syntax
:SEQuence:POIN:TIME? [MAX|MIN]
Przeglądanie stron 151
1 2 ... 147 148 149 150 151 152 153 154 155 156 157 ... 169 170

Komentarze do niniejszej Instrukcji

Brak uwag