COMMAND DETAILS
157
Example
:SEQ:TRIG:IN 0
Trigger IN is on.
Query Syntax
:SEQuence:TRIGger:IN?
Return Parameter
<NR1>
Trigger IN
0
Off
1
On
Query Example
:SEQ:TRIG:IN?
1
Trigger IN is on.
:SEQuence:TRIGger:OUT
Channel Specific
Command
Description
Turns the trigger output on for the selected
channel for sequences. Note that one channel must
be set for trigger out.
Syntax
:SEQuence:TRIGger:OUT <NR1>|MIN|MAX
Parameter
<NR1>
Channel number
MAX
Sets TRIG OUT to the last
channel
MIN
Sets TRIG OUT to the
first channel
Example
:SEQ:TRIG:OUT 1
Sets TRIG OUT to CH1.
Query Syntax
:SEQuence:TRIGger:OUT?
Return Parameter
<NR1>
Channel number
MAX/MIN
Last or first channel.
Query Example
:SEQ:TRIG:OUT?
1
CH1 is set to TRIG OUT.
:SEQuence:TRIGger:IN:CHANnel
Channel Specific
Command
Description
Selects which channels are turned on/off with
the :SEQuence:TRIGger:IN command. The bit
weight of the <NR1> value determines which
channels are used.