COMMNAND OVERVIEW
51
Returns the delay time in
seconds.
:GNG:DTIMe 0.5
Sets the delay time to 0.5 seconds.
:GNG:DTIMe?
>0.5
The delay time is 0.5 seconds.
Sets or queries the entry mode for the Go-NoGo
settings. The entry mode determines whether the
Go-NoGo limits are set as values or as a
percentage value from a center reference value.
[:CONFigure]:GNG:MODE {PERCent | VALue }
Sets the entry mode to %.
Sets the entry mode to
value
:GNG:MODE PERCent
Sets the entry mode to %.
:GNG:MODE?
>Percent
The entry mode is %.
Queries the Go-NoGo test result(s). This command
can be used for all test modes (CC, CV, CR, CP).