Gw-instek PEL-3000 Series Programming Manual Instrukcja Użytkownika Strona 47

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 174
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 46
COMMNAND OVERVIEW
45
[:CONFigure]:VON
Set
Query
Description
Sets or queries the Von voltage settings.
Syntax
[:CONFigure]:VON {<NRf>[ V ] | MINimum|
MAXimum | LON | LOFF }
Query Syntax
[:CONFigure]:VON?
Parameter
{<NRf>[ V ]
The Von voltage level
(default unit is V)
MINIMUM or MIN
Minimum Von voltage
level
MAXIMUM or MAX
Maximum Von voltage
level
LON
Latch on
LOFF
Latch off
Return parameter
<ASCII string>
Returns the Von latch
settings.
Example
:VON 10.0V
Sets the Von voltage to 10.0 volts.
Query example
:VON?
>Latch OFF, 10.000
The Von voltage level is 10V.
[:CONFigure]:VDELay
Set
Query
Description
Sets or queries the Von Delay settings in seconds.
Syntax
[:CONFigure]:VDELay {<NRf>[s] | MINimum |
MAXimum | OFF }
Query Syntax
[:CONFigure]:VDELay?
Parameter
<NRf>[s]
The delay time in seconds
OFF
Disable the delay time
MINIMUM or MIN
Minimum delay time
MAXIMUM or MAX
Maximum delay time
Return parameter
<NR2>
Returns the delay time in
seconds