Gw-instek GSP-930 Programming Manual Instrukcja Użytkownika Strona 80

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 195
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 79
GSP-930 Programming Manual
78
:CALCulate:LIMit<n>:MARKer
Set
Sets the current marker position to a point on a
limit line. The vertical position of the point is the
marker’s vertical position + a user-defined offset.
:CALCulate:LIMit<n>:MARKer <point>,<offset>
<point>
<NR1> point 1~10
<offset>
<NR3> dB
<n>
Seleted limit line
:CALC:LIM1:MARK 5, 20
:CALCulate:LIMit:PASS:MODE
Set
Query
Sets or queries the Pass/Fail conditions for the
limit line testing.
:CALCulate:LIMit:PASS:MODE {ALL|MAX|MIN}
:CALCulate:LIMit:PASS:MODE?
ALL
All-in.
MAX
Max-In
MIN
Min-In
:CALC:LIM:PASS:MODE ALL
:CALCulate:LIMit:STATe
Set
Query
Turns the limit line Pass/Fail test on/off.
:CALCulate:LIMit:STATe {ON|OFF|1|0}
:CALCulate:LIMit:STATe?
0
Pass/Fail test is off.
1
Pass/Fail test is on.
OFF
Pass/Fail test is off.
ON
Pass/Fail test is on.
0
Pass/Fail test is off.
1
Pass/Fail test is on.
Przeglądanie stron 79
1 2 ... 75 76 77 78 79 80 81 82 83 84 85 ... 194 195

Komentarze do niniejszej Instrukcji

Brak uwag