REMOTE CONTROL
189
:TRIGger[:SEQuence]:DEMod:LEVel
Set
Query
Description
Sets the trigger level for AM/FM demodulation.
Syntax
:TRIGger[:SEQuence]:DEMod:LEVel <NRf>
Query Syntax
:TRIGger[:SEQuence]:DEMod:LEVel?
Parameter
<NRf>
AM unit =%
FM unit = Hz
Return parameter
<NR3>
Example
:TRIG:DEM:LEV 10
:TRIGger[:SEQuence]:DEMod:MODE
Set
Query
Description
Sets the triggering mode for the AF Trigger in
AM/FM demodulation.
Syntax
:TRIGger[:SEQuence]:DEMod:MODE
{NORMal|SINGle|CONTinuous}
Query Syntax
:TRIGger[:SEQuence]:DEMod:MODE?
Parameter/
Return parameter
NORMal
Normal trigger mode
SINGle
Single trigger
CONTinuous
Continuous trigger
Example
:TRIG:DEM:MODE CONT
:TRIGger[:SEQuence]:DEMod:SLOPe
Set
Query
Description
Sets the trigger slope.
Syntax
:TRIGger[:SEQuence]:DEMod:SLOPe
{POSitive|NEGative}
Query Syntax
:TRIGger[:SEQuence]:DEMod:SLOPe?
Parameter/
Return parameter
POSitive
Positive slope
NEGative
Negative slope
Example
:TRIG:DEM:SLOP POS