GSP-930 Programming Manual
108
INPut Commands
:INPut:ATTenuation ........................................................... 108
:INPut:ATTenuation:AUTO ............................................. 108
:INPut:IMPedance ............................................................... 109
:INPut:OFFSet ..................................................................... 109
:INPut:ATTenuation
Set
Query
Sets or queries the input attenuation.
:INPut:ATTenuation <integer>
:INPut:ATTenuation?
<integer>
<NR1> 0 to 50
:INP:ATT 10 dB
:INPut:ATTenuation:AUTO
Set
Query
Sets or queries whether the automatic input
attenuation is on/off.
:INPut:ATTenuation:AUTO {OFF|ON|0|1}
:INPut:ATTenuation:AUTO?
0
Turn automatic input attenuation off.
1
Turn automatic input attenuation on.
OFF
Turn automatic input attenuation off.
ON
Turn automatic input attenuation on.
0
Automatic input attenuation is off.
1
Automatic input attenuation is on.
:INP:ATT:AUTO ON