Example
:MEASure:SOURce1 CH1
:MEASure:MAX?
1.90E-3
Selects Channel 1, and then measures the
maximum amplitude.
:MEASure:MIN
Description
Returns the minimum amplitude.
Syntax
:MEASure:MIN?
Related
Commands
:MEASure:SOURce<X>
Return parameter
<NR3>
Returns the minimum amplitude.
Chan Off
Indicates the source channel is not
activated.
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH1
:MEASure:MIN?
-8.00E-3
Selects Channel 1, and then measures the
minimum amplitude.
:MEASure:AMPlitude
Description
Returns the amplitude difference between the
Vhigh-Vlow.
Syntax
:MEASure:AMPlitude?
Related
Commands
:MEASure:SOURce<X>
Return parameter
<NR3>
Returns the amplitude.