Parameter
<X>
Channel number (1 to 2)
Return parameter
0
Raw data is not ready
1
Raw data is ready
Example
:ACQuire1:STATe?
0
Returns 0. The channel 1’s raw data is not ready.
:ACQuire:INTERpolation
Description
Selects or returns the interpolation mode.
Syntax
:ACQuire:INTERpolation {ET | SINC | ?}
Parameter/Return
parameter
ET
Set the Equivalent Time interpolation.
SINC
Sets to SIN(X)/X interpolation
Example
:ACQuire:INTERpolation ET
Sets the scope to ET interpolation.
:ACQuire:RECOrdlength
Description
Sets or queries the record length. Please see the
user manual for full details.
Syntax
:ACQuire:RECOrdlength {<NRf> | ?}
Parameter/Return
parameter
<NRf>
1e+3, 1e+4, 1e+5, 1e+6, 5e+6 (GDS-300
only)
Example
:ACQuire:RECOrdlength?
1.000000e+04
The record length is currently set to 10000.