COMMAND DETAILS
113
Parameter
<string>
Max. 50 character string enclosed in
double quotes.
Example
:SAVE:ALL:NOTE “This is a note.”
Saves the note the next time the SAVe:ALL
command is used.
:BRIEF:MODe
Description
Turns the brief mode on or off. This is only
applicable when saving image files.
Syntax
:BRIEF:MODe {ON | OFF | ?}
Related
commands
:SAVe:IMAGe
Parameter/
Return parameter
ON
Turns Brief mode on
OFF
Turns Brief mode off
Example
:BRIEF:MODe ON
Turns brief mode on.
:BRIEF:DATE
Description
Adds the time and date to the image file that is
saved when Brief mode is on.
Syntax
:BRIEF:DATE {ON | OFF | ?}
Related
commands
:SAVe:IMAGe
Parameter/
Return parameter
ON
Adds date and time for Brief mode
OFF
Turns off the date and time from Brief
mode
Example
:BRIEF:DATE ON
Adds the date and time to Brief mode.