Return parameter
Returns the riser overshoot as <NR3>
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH 1
:MEASure:RPReshoot?
2.13E-2
Selects Channel 1, and then measures the rise
preshoot.
:MEASure:AMPlitude
Query
Description
Returns the amplitude difference between the
Vhigh-Vlow.
Syntax
:MEASure:AMPlitude{?}
Return parameter
Returns the amplitude as <NR3>
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH 1
:MEASure:AMPlitude?
3.76E-3
Selects Channel 1, and then measures the
amplitude.
:MEASure:AVERage
Query
Description
Returns the average voltage/current of one or
more fully period.
Syntax
:MEASure:AVERage{?}
Return parameter
Returns the average as <NR3>
Note
Before using this command, select the
measurement channel. See the example below.