COMMAND DETAILS
171
Related
commands
:BUS1:STATE
Parameter/Return
parameter
UART
Sets the bus to UART mode.
I2C
Sets the bus to I
2
C mode.
SPI
Sets the bus to SPI mode.
PARallel
Sets the bus to parallel mode.
Example
:BUS1:TYPe SPI
Sets the bus to SPI mode.
:BUS1:I2C:ADDRess:RWINClude
Description
Sets or queries whether the read/write bit is
included in the I
2
C address.
Syntax
:BUS1:I2C:ADDRess:RWINClude { OFF | ON | ? }
Related
commands
:BUS1:STATE
Parameter
OFF
The R/W is not included.
ON
The R/W is included.
Return parameter
0
The R/W is not included.
1
The R/W is included.
Example
:BUS1:I2C:ADDRess:RWINClude ON
Includes the R/W bit in the I
2
C address.
:BUS1:I2C:SCLK:SOURce
Description
Sets or queries which channel is used for the I
2
C
SCLK source.
Syntax
:BUS1:I2C:SCLK:SOURce { D0 | D1 | D2 | D3 | D4 | D5
| D6 | D7 | D8 | D9 | D10 | D11 | D12 | D13 | D14 | D15
| ? }
Parameter/Return
parameter
D0 to D15
Digital channels D0 to D15
Set
Query
Set
Query