COMMAND DETAILS
115
Timebase Commands
:TIMebase:EXPand ....................................................115
:TIMebase:POSition ..................................................115
:TIMebase:SCALe .......................................................116
:TIMebase:MODe ......................................................116
:TIMebase:WINDow:POSition ..................................116
:TIMebase:WINDow:SCALe ......................................117
:TIMebase:EXPand
Description
Sets or queries the horizontal expansion mode.
Only available for firmware V1.18 or above.
Note
Requires the Horizontal Expansion app. Available
for download on the GW Instek website.
Syntax
:TIMebase:EXPand {CENTer|TRIGger|?}
Parameter/Return
parameter
CENTer
Expand from the center of the
display.
TRIGger
Expand from the trigger point.
Example
:TIMebase:EXPand TRIGger
Sets the expansion point to the trigger point.
:TIMebase:POSition
Description
Sets or queries the horizontal position.
Syntax
:TIMebase:POSition {<NRf> | ?}
Parameter
<NRf>
Horizontal position
Return parameter
<NR3>
Returns the horizontal position.
Example
:TIMebase:POSition 5.00E-4
Sets the horizontal position as 500us.
Set
Query
Set
Query