Parameter
<sting>
The number of characters in the string
depends on the data size setting. The
string must be enclosed in double
quotes, "string".
x = don’t care
1 = binary 1
0 = binary 0
Return Parameter
Returns the data value.
Example1
:TRIGger:BUS:B1:UART:CONDition TXDATA
:TRIGger:BUS:B1:UART:TX:DATa:SIZe 1
:TRIGger:BUS:B1:UART:TX:DATa:VALue "1x1x0101"
Sets the value to 1x1x0101
Example 2
:TRIGger:BUS:B1:UART:TX:DATa:VALue?
1X1X0101
:TRIGger:BUS:B1:SPI:CONDition
Description
Sets or queries the SPI triggering condition.
Syntax
:TRIGger:BUS:B1:SPI:CONDition {SS | MISO | MOSI |
MISOMOSI | ? }
Parameter
SS
Set to trigger on the Slave Selection
condition.
MISO
Set to trigger on the Master-In
Slave-Out condition.
MOSI
Set to trigger on the Master-Out
Slave-In condition.
MISOMOSI
Set to trigger on the Master-In
Slave-Out and Master-Out Slave-In
conditions.
Return Parameter
Returns the triggering condition.
Example
:TRIGger:BUS:B1:SPI:CONDition MISO
Sets the SPI bus to trigger on MISO.
Set