Gw-instek GDS-1000A-U Series Programming Manual Instrukcja Użytkownika Strona 43

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 88
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 42
COMMAND DETAILS
43
:MEASure:DELAY1
Set
Query
Description
Sets or returns the first source channel for the
delay automatic measurement.
Same as: Measure key → F1~F5 → F3 →Select
delay measurement function→ F1 (Source1)
Syntax
< Long >
< Short >
:measure:delay1 <NR1>
:measure:delay1?
:meas:delay1 <NR1>
:meas:delay1?
Parameter
<NR1>
1 ~ 2
Channel1 ~ 2
Example
:measure:delay1 1
Select Channel1 as the
first source channel.
:MEASure:DELAY2
Set
Query
Description
Sets or returns the second source channel for the
delay automatic measurement.
Same as: Measure key → F1~F5 →F3→Select delay
measurement function→F2 (Source2)
Syntax
< Long >
< Short >
:measure:delay2 <NR1>
:measure:delay2?
:meas:delay2 <NR1>
:meas:delay2?
Parameter
<NR1>
1~2
Channel1~2
Example
:measure:delay2 1
Select Channel1 as the
second source
channel.
Przeglądanie stron 42
1 2 ... 38 39 40 41 42 43 44 45 46 47 48 ... 87 88

Komentarze do niniejszej Instrukcji

Brak uwag