REMOTE CONTROL
83
VOLT:EXT:SOUR?
NONE
External control is not used.
[:SOURce]:VOLTage[0][:LEVel][:IMMediate]
[:AMPLitude]
Sets or queries the voltage level in volts.
[:SOURce]:VOLTage[0][:LEVel][:IMMediate][:AMPLitude
] {<NR2>(V)|MINimum|MAXimum}
[:SOURce]:VOLTage[0][:LEVel][:IMMediate][:AMPLitude
]?
0~105% of the rated output voltage in volts.
Returns the voltage level in volts
SOUR:VOLT:LEV:IMM:AMPL 10
Sets the voltage level to 10 volts.
[:SOURce]:VOLTage[0][:LEVel]:TRIGgered
[:AMPLitude]
Sets or queries the voltage level in volts when a
software trigger has been generated.
[:SOURce]:VOLTage[0][:LEVel]:TRIGgered[:AMPLitude]
{<NR2>(V)|MINimum|MAXimum}
[:SOURce]:VOLTage[0][:LEVel]:TRIGgered[:AMPLitude]?
0%~105% of the rated voltage output in volts.
Returns the voltage level.
SOUR:VOLT:LEV:TRIG:AMPL 10
Sets the voltage level to 10 volts when a software
trigger is generated.