REMOTE CONTROL
43
4. Terminate the OUT port of the last unit with
the end terminal connector included in the
PSU-232 or PSU-485 connection kit.
5. Press the Function key to enter the
Normal configuration settings for
the master unit.
Set the following settings:
Configure the master unit as you
normally would for RS232 or
RS485 remote control.
Set the baud rate (set all units
the same).
Set the UART TCP to TDK
(emulation mode).
Set the address of the master
unit. It must be a unique
address identifier.
6. Press the Function key to enter the
Normal configuration settings for
the slave(s).
Set the following settings:
Set the slave unit to RS485.
Set the baud rate (make all
units, including the master, the
same baud).
Set the UART TCP to TDK
(emulation mode).