:MEASure:VAVerage
Query
Returns the average voltage.
Same as: Measure key F1~F5 F3 (Vavg)
< Long >
< Short >
:measure:vaverage?
:meas:vavg?
<NR3>
Select the measurement channel before this
command: :measure:source <NR1>. See pagexx.
:measure:source 1
:measure:vaverage?
Select channel 1, then
measure average
Voltage.
:MEASure:VHI
Query
Returns the global high voltage.
Same as: Measure key F1~F5 F3 (Vhi)
< Long >
< Short >
:measure:vhi?
:meas:vhi?
<NR3>
Select the measurement channel before this
command: :measure:source <NR1>. See pagexx.
:measure:source 1
:measure:vhi?
Select channel 1, then
measure global high
Voltage.