COMMAND SET
55
:MEASure:DELAY2
Set
Query
Sets or returns the second source channel for the
delay automatic measurement.
Same as: Measure key F1~F5 F2 (Source2)
< Long >
< Short >
:measure:delay2 <NR1>
:measure:delay2?
:meas:delay2 <NR1>
:meas:delay2?
<NR1>
1 ~ 4
Channel1 ~ 4
:measure:delay1 1
Select Channel1 as the
second source channel.
:MEASure:FALL
Query
Returns the falltime measurement result.
Same as: Measure key F1~F5 F3 (Fall Time)
< Long >
< Short >
:measure:fall?
:meas:fall?
<NR3>
Select the measurement channel before this
command: :measure:source <NR1>. See pagexx.
:measure:source 1
:measure:fall?
Select channel 1, then
measure fall time.
Przeglądanie stron 54