Digital Storage Oscilloscope
GBS-1000 Series
PROGRAMMING MANUAL
GW INSTEK PART NO. 82BS-12040M01
ISO-9001 CERTIFIED MANUFACTURER
Przeglądanie stron 0
1 2 3 4 5 6 ... 87 88

Podsumowanie treści

Strona 1 - Digital Storage Oscilloscope

Digital Storage Oscilloscope GBS-1000 Series PROGRAMMING MANUAL GW INSTEK PART NO. 82BS-12040M01 ISO-9001 CERTIFIED MANUFACTURER

Strona 2

GBS-1000 Programming Manual 10

Strona 3 - Table of Contents

COMMAND SET 11 COMMAND SET Command List System *IDN?... ...17 *LRN?...

Strona 4 - CONFIGURATION

GBS-1000 Programming Manual 12 Display :DISPlay:ACCumulate ... 36 :DISPlay:CONTrast ...

Strona 5 - Interface Overview

COMMAND SET 13 Measure :MEASure:DELAY1 ... 54 :MEASure:DELAY2 ...

Strona 6

GBS-1000 Programming Manual 14 Memory :MEMory<X>:RECall:SETup ... 70 :MEMory<X>:RECall:WAVeform .

Strona 7 - USB interface Configuration

COMMAND SET 15 Time :TIMebase:DELay ... 86 :TIMebase:SCALe ...

Strona 8 - Stop Bit

GBS-1000 Programming Manual 16 Command Syntax Compatible standard  IEEE488.2, 1992 (fully compatible)  SCPI, 1994 (partially compatible) Comm

Strona 9 - 1 2 3 4 5

COMMAND SET 17 System Commands *IDN?...17 *LRN?... ...

Strona 10

GBS-1000 Programming Manual 18 0;SOURce 0;ADVance:DELay 1.000E-07;EVENt 3;LEVel 1.480E+00;MODe 0;TYPe 0;PULSe:TIMe 1.000E+01;MODe: 1;TV:FIELd 1;LI

Strona 11 - COMMAND SET

COMMAND SET 19 *RCL Set Description Recalls a set of panel setting from one of the twenty internal memories, S1 to S20. Same as: Save/Recall key

Strona 12

This manual contains proprietary information, which is protected by copyrights. All rights are reserved. No part of this manual may be photocopied,

Strona 13

GBS-1000 Programming Manual 20 Acquisition Command :ACQuire:AVERage ... 20 :ACQuire:LENGth ..

Strona 14

COMMAND SET 21 :ACQuire:LENGth SetQuery Description Selects or returns the memory length. Same as: Acquire key → F5 Syntax < Long > <

Strona 15

GBS-1000 Programming Manual 22 :ACQuire:MEMory Query Description Returns the total waveform data from the acquisition memory. Syntax < Long &

Strona 16 - Command Syntax

COMMAND SET 23 Auto Set Command :AUToset Set Description Runs Auto Set (automatically configures horizontal scale, vertical scale, trigger accord

Strona 17 - System Commands

GBS-1000 Programming Manual 24 Channel / Math Command :CHANnel<X>:BWLimit ... 24 :CHANnel<X

Strona 18

COMMAND SET 25 :CHANnel<X>:COUPling SetQuery Description Selects or returns the coupling mode for each channel. Same as: Channel key → F1

Strona 19

GBS-1000 Programming Manual 26 :CHANnel<X>:EXPand SetQuery Description Sets the expansion mode as from ground or from center for a selected

Strona 20 - Acquisition Command

COMMAND SET 27 :CHANnel<X>:MATH SetQuery Description Selects or returns the math operation. Same as: Math key → F1 Syntax < Long > &

Strona 21 - :ACQuire:MODe

GBS-1000 Programming Manual 28 :CHANnel<X>:OFFSet SetQuery Description Sets or returns the offset level for each channel. The offset level

Strona 22 - :ACQuire:HORexpand

COMMAND SET 29 :CHANnel<X>:SCALe SetQuery Description Sets or returns the vertical scale for each channel. The scale is dependent on the p

Strona 23 - Auto Set Command

TABLE OF CONTENTS 3 Table of Contents CONFIGURATION ... 4 Interface Overview ...

Strona 24 - Channel / Math Command

GBS-1000 Programming Manual 30 Data Log Commands :DATALOG:STATE ... 30 :DATALOG:SOURce ...

Strona 25 - :CHANnel<X>:DISPlay

COMMAND SET 31 4 Sets CH4 as the source channel 5 Sets Math as the source channel Example :DATALOG:SOUR 1 Set source as CH1. :DATALOG:SAVe SetQu

Strona 26 - :CHANnel<X>:INVert

GBS-1000 Programming Manual 32 Syntax < Long > < Short > :DATALOG:DURation <NR1> :DATALOG:DURation? :DATALOG:DUR <NR1>

Strona 27 - :CHANnel<X>:MATH

COMMAND SET 33 Cursor Command :CURSor:X<X>Position ... 33 :CURSor:Y<X>Position ...

Strona 28 - :CHANnel<X>:PROBe

GBS-1000 Programming Manual 34 Parameter <X> Cursor 1 or 2 <NR1> Cursor position 1 Cursor V1 1 ~ 199 1 ~ 199 point 2 Cursor V2 Exa

Strona 29 - :CHANnel<X>:SCALe

COMMAND SET 35 :CURSor:SOURce SetQuery Description Selects or returns the cursor source channel. Same as: Cursor key →F1 (Source) Syntax < Lon

Strona 30 - Data Log Commands

GBS-1000 Programming Manual 36 Display Command :DISPlay:ACCumulate ... 36 :DISPlay:CONTrast ...

Strona 31

COMMAND SET 37 :DISPlay:CONTrast SetQuery Description Sets or returns the display contrast level. Same as: Display key → F4 (Contrast) Syntax &l

Strona 32

GBS-1000 Programming Manual 38 :DISPlay:WAVEform SetQuery Description Sets or returns the display waveform type. Same as: Display key → F1 (Type

Strona 33 - Cursor Command

COMMAND SET 39 Go-NoGo Command :GONogo:FUNction ... 39 :GONogo:CLEar ...

Strona 34 - :CURSor:<X>DISplay

GBS-1000 Programming Manual 4 CONFIGURATION This chapter describes how to configure GBS-1000 remote control interface. GBS-1000 series overview

Strona 35 - :CURSor:SOURce

GBS-1000 Programming Manual 40 :GONogo:CLEar Set Description Clears Go-No Go test total number/ failure number counter on the display. Same as:

Strona 36 - Display Command

COMMAND SET 41 :GONogo:NGCount? Query Description Returns Go-No Go test total and fail count. Same as: Utility key → F5 (More) → F3 (Go-NoGo Men

Strona 37 - :DISPlay:GRATicule

GBS-1000 Programming Manual 42 :GONogo:SOURce SetQuery Description Sets or returns Go-No Go test source channel. Same as: Utility key → F5 (More

Strona 38 - :REFResh

COMMAND SET 43 :TEMPlate:MAX SetQuery Description Sets or returns Go-No Go Max template. Same as: Utility key → F5 (More) → F3 (Go-NoGo Menu) →

Strona 39 - Go-NoGo Command

GBS-1000 Programming Manual 44 :TEMPlate:MIN SetQuery Description Sets or returns Go-No Go Min template. Same as: Utility key → F5 (More) → F3 (

Strona 40 - :GONogo:EXECute

COMMAND SET 45 :TEMPlate:MODe SetQuery Description Sets or returns Go-No Go test template mode. Same as: Utility key → F5 (More) → F3 (Go-NoGo M

Strona 41 - :GONogo:NGDefine

GBS-1000 Programming Manual 46 :TEMPlate:POSition:MAX SetQuery Description Sets or returns Go-NoGo Max template position. Same as: Utility key →

Strona 42 - :GONogo:VIOLation

COMMAND SET 47 :TEMPlate:POSition:MIN SetQuery Description Sets or returns Go-NoGo Min template position. Same as: Utility key → F5 (More) → F3

Strona 43 - :TEMPlate:MAX

GBS-1000 Programming Manual 48 :TEMPlate:SAVe:AUTo Set Description Saves Go-NoGo test Auto template. Same as: Utility key → F5 (More) → F3 (Go-N

Strona 44 - :TEMPlate:MIN

COMMAND SET 49 :TEMPlate:TOLerance SetQuery Description Sets or returns Go-NoGo Auto template tolerance. Same as: Utility key → F5 (More) → F3 (

Strona 45 - :TEMPlate:MODe

CONFIGURATION 5 Interface Overview Rear panel 

Strona 46 - :TEMPlate:POSition:MAX

GBS-1000 Programming Manual 50 Hardcopy Command :COPY…………… ... 50 :HARDcopy:INKSaver ..

Strona 47 - :TEMPlate:POSition:MIN

COMMAND SET 51 :HARDcopy:LAYout SetQuery Description Selects or returns printout color in Hardcopy Printer mode. Same as: Utility key → F1(Hardc

Strona 48 - :TEMPlate:SAVe:MINimum

GBS-1000 Programming Manual 52 :HARDcopy:RATio SetQuery Description Selects or returns Hardcopy printout ratio relative to the paper size. Same

Strona 49 - :TEMPlate:TOLerance

COMMAND SET 53 Measure command :MEASure:DELAY1 ... 54 :MEASure:DELAY2 ...

Strona 50 - Hardcopy Command

GBS-1000 Programming Manual 54 :MEASure:DELAY1 SetQuery Description Sets or returns the first source channel for the delay automatic measurement.

Strona 51 - :HARDcopy:MODe

COMMAND SET 55 :MEASure:DELAY2 SetQuery Description Sets or returns the second source channel for the delay automatic measurement. Same as: Meas

Strona 52 - :HARDcopy:RATio

GBS-1000 Programming Manual 56 :MEASure:FFFDelay Query Description Returns the delay between the first falling edge of source1 and the first fal

Strona 53 - Measure command

COMMAND SET 57 :MEASure:FOVShoot Query Description Returns fall overshoot amplitude in percentage. Same as: Measure key → F1~F5 → F3 (FOVShoot)

Strona 54 - :MEASure:DELAY1

GBS-1000 Programming Manual 58 :MEASure:FREQuency? Query Description Returns the frequency value. Same as: Measure key → F1~F5 → F3 (Frequency)

Strona 55 - :MEASure:FALL

COMMAND SET 59 :MEASure:FRRDelay Query Description Returns the delay between the first rising edge of source1 and the first rising edge of sourc

Strona 56 - :MEASure:FFRDelay

GBS-1000 Programming Manual 6 Functionality check Run this query command via the terminal. *idn? This should return the Manufacturer, Model number

Strona 57 - :MEASure:FPReshoot

GBS-1000 Programming Manual 60 :MEASure:LFRDelay Query Description Returns the delay between the first falling edge of source1 and the last risi

Strona 58 - :MEASure:FRFDelay

COMMAND SET 61 :MEASure:LRRDelay Query Description Returns the delay between the first rising edge of source1 and the last rising edge of source

Strona 59 - :MEASure:LFFDelay

GBS-1000 Programming Manual 62 :MEASure:PDUTy? Query Description Returns the positive duty cycle ratio. Same as: Measure key → F1~F5 → F3 (DutyC

Strona 60 - :MEASure:LRFDelay

COMMAND SET 63 :MEASure:PWIDth? Query Description Returns the first positive pulse width. Same as: Measure key → F1~F5 → F3 (+Width) Syntax <

Strona 61 - :MEASure:NWIDth

GBS-1000 Programming Manual 64 :MEASure:ROVShoot Query Description Returns rise overshoot amplitude in percentage. Same as: Measure key → F1~F5

Strona 62 - :MEASure:PERiod?

COMMAND SET 65 :MEASure:SOURce SetQuery Description Selects the measurement channel. Same as: Measure key → F1~F5 → F1, F2 Syntax < Long >

Strona 63 - :MEASure:RISe?

GBS-1000 Programming Manual 66 :MEASure:VAVerage Query Description Returns the average voltage. Same as: Measure key → F1~F5 → F3 (Vavg) Syntax

Strona 64 - :MEASure:RPReShoot

COMMAND SET 67 :MEASure:VLO Query Description Returns the global low voltage. Same as: Measure key → F1~F5 → F3 (Vlo) Syntax < Long > <

Strona 65 - :MEASure:VAMPlitude

GBS-1000 Programming Manual 68 :MEASure:VMAX Query Description Returns the maximum amplitude. Same as: Measure key → F1~F5 → F3 (Vmax) Syntax &l

Strona 66 - :MEASure:VHI

COMMAND SET 69 :MEASure:VPP Query Description Returns the peak-to-peak amplitude (difference between maximum and minimum amplitude) Same as: Mea

Strona 67 - :MEASure:VMAX

CONFIGURATION 7 USB interface Configuration USB configuration PC side connector Type A, host GBS-1000 side connector Type B, slave Speed 1.1/2.0

Strona 68 - :MEASure:VMIN

GBS-1000 Programming Manual 70 Memory (Save/Recall) Command :MEMory<X>:RECall:SETup ... 70 :MEMory<

Strona 69 - :MEASure:VRMS

COMMAND SET 71 :MEMory<X>:RECall:WAVeform Set Description Recalls a waveform from the internal memory and saves to a reference waveform. Sa

Strona 70 - Memory (Save/Recall) Command

GBS-1000 Programming Manual 72 :MEMory<X>:SAVe:WAVeform Set Description Saves a reference waveform to internal memory. Same as: Save/Recall

Strona 71 - :MEMory<X>:SAVe:SETup

COMMAND SET 73 Syntax < Long > < Short > :ref<x>:display <Boolean> :ref<x>:display? :ref<x>disp <Boolean&g

Strona 72 - :REF<X>:DISPlay

GBS-1000 Programming Manual 74 :REF<X>:SAVe Set Description Saves an input signal as a reference waveform. Same as: Save/Recall key → F4(Sa

Strona 73 - :REF<X>:LOCate

COMMAND SET 75 :USB:RECall:WAVeform Set Description Recalls a waveform from the USB and saves to a reference waveform. (Note: Only the last saved

Strona 74 - :USB:RECall:SETup

GBS-1000 Programming Manual 76 :USB:SAVe:SETup Set Description Saves the current setup to the USB flash drive. Same as: Save/Recall key → F3(Save

Strona 75 - :USB:SAVe:IMAGe

COMMAND SET 77 Run/Stop Commands :RUN….. ………………………………………………………………77 :STOP…. ………………………………………………………………77 :RUN Set Description Controls the RUN s

Strona 76 - :USB:SAVe:WAVeform

GBS-1000 Programming Manual 78 Trigger Commands :TRIGger:COUPle ... 78 :TRIGger:FREQuency

Strona 77 - Run/Stop Commands

COMMAND SET 79 :TRIGger:FREQuency SetQuery Description Returns the readout value of the trigger frequency counter. Syntax < Long > < Sho

Strona 78 - Trigger Commands

GBS-1000 Programming Manual 8 RS-232C Interface Configuration RS-232C configuration Connector DB-9, Male Baud rate 2400, 4800, 9600, 19200, 38400

Strona 79

GBS-1000 Programming Manual 80 1 Auto 2 Normal 3 Single Example :trigger:mode 1 Sets the trigger mode to AUTO. :TRIGger:NREJ SetQuery Descript

Strona 80 - :TRIGger:NREJ

COMMAND SET 81 1 > 2 = 3 ≠ Example :trigger:pulse:mode 1 Sets the triggering condition to “>”. :TRIGger:PULSe:TIMe SetQuery Description

Strona 81 - :TRIGger:REJect

GBS-1000 Programming Manual 82 2 High frequency rejection Example :trigger:reject 0 Turns frequency rejection off. :TRIGger:SLOPe SetQuery Descr

Strona 82 - :TRIGger:SOURce

COMMAND SET 83 Example :trigger:source 0 Sets the trigger source to CH1. :TRIGger:TYPe SetQuery Description Sets or queries the trigger type. Sam

Strona 83 - :TRIGger:VIDeo:FIELd

GBS-1000 Programming Manual 84 :TRIGger:VIDeo:LINe SetQuery Description Sets or queries which specific line to trigger on. Same as: Trigger MENU

Strona 84 - :TRIGger:VIDeo:POLarity

COMMAND SET 85 :TRIGger:VIDeo:TYPe SetQuery Description Sets or queries the video trigger standard. Same as: Trigger MENU key → F3 (Standard). (N

Strona 85 - :TRIGger:VIDeo:TYPe

GBS-1000 Programming Manual 86 Time (horizontal) Commands :TIMebase:DELay ... 86 :TIMebase

Strona 86 - Time (horizontal) Commands

COMMAND SET 87 5ns 5e-9 25us 25e-6 100ms 100e-3 10ns 10e-9 50us 50e-6 250ms 250e-3 25ns 25e-9 100us 100e-6 500ms 500e-3 50ns 50e-9 250us 250e-

Strona 87 - :TIMebase:SWEep

GBS-1000 Programming Manual 88 :TIMebase:WINDow:DELay SetQuery Description Sets or returns the zoomed window horizontal position in seconds. Same

Strona 88 - :TIMebase:WINDow:SCALe

CONFIGURATION 9 Range None, Odd, Even 9. Connect the RS-232C cable to the rear panel port: DB-9 male connector.  Pin assignment 1 2 3 4 5