REMOTE CONTROL
63
Sense Commands
SENSe:AVERage:COUNt ................................................... 63
SENSe:AVERage:COUNt
Set
Query
Description
Determines the level of smoothing for the average
setting. This is the equivalent to the F-17 function
setting.
Syntax
Query Syntax
SENSe:AVERage:COUNt {<NR1>| LOW | MIDDle |
HIGH}
SENSe:AVERage:COUNt?
Parameter
0 | LOW
Low level of smoothing.
1 | MIDDle
Middle level of smoothing.
2 | HIGH
High level of smoothing.
Return parameter
<NR1>
Returns the level of smoothing.
0
Low level of smoothing.
1
Middle level of smoothing.
2
High level of smoothing.
Example
SENSe:AVERage:COUNt 1
Sets the level of smoothing to middle.