Gw-instek GDM-8246 Programming Manual Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Ekwipunek Gw-instek GDM-8246 Programming Manual. GW Instek GDM-8246 Programming Manual User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 28
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
GDM-8246 MULTIMETER
PROGRAMMER MANUAL
1
CONTENTS PAGE
1.
INTRODUCTION.............................................................................
1
2. CONNECTING DMM VIA GPIB INTERFACE……………...
2
3. CONNECTING DMM VIA RS232 INTERFACE…………….
5
4.
INPUT AND OUTPUT QUEUE………………………………..
8
5. COMMANDS AND SYNTAX………………………………….
8
6. DETAILS OF COMMAND REFERENCE……………………
21
7. STATUS AND ERROR REPORTING………………………....
46
GDM-8246 MULTIMETER
PROGRAMMER MANUAL
1
1. INTRODUCTION
In the modern automatic measurement system, communication
between equipments and computers is essential. The measured
procedures can be varied with user’s testing programs, therefore, the
Digital Multimeter can be operated remotely from an instrument
controller or computer across the RS232 interface (optional) or GPIB
(optional).
Interface selection and setup
Press [SHIFT][SET] in sequence into SET mode, then press [RS-232] or
[GPIB] the white characters with blue background to set the RS232 OR
GPIB interface. If the indicator of negative sine lights, the value
displayed on the front panel is the current setting value. Use [][] can
adjust the baud rate (or GPIB address). Finally, press [ENTER] to store
the setup or press [SHIFT] to cancel the setup.
Przeglądanie stron 0
1 2 3 4 5 6 ... 27 28

Podsumowanie treści

Strona 1 - 1. INTRODUCTION

GDM-8246 MULTIMETER PROGRAMMER MANUAL ⎯ ⎯ 1 CONTENTS PAGE 1. INTRODUCTION...

Strona 2 - GPIB INTERFACE

GDM-8246 MULTIMETER PROGRAMMER MANUAL ⎯ 18 ⎯ :CALCulation:SDMB:STATe? Returns DBM mode on or off. :CALCulation: SDMB:STATe <Boolean> Sets D

Strona 3 - THE DIGITAL MULTIMETER VIA

GDM-8246 MULTIMETER PROGRAMMER MANUAL ⎯ 20 ⎯ z Miscellaneous Commands Table 4 lists the miscellaneous commands that control general housekeeping

Strona 4

GDM-8246 MULTIMETER PROGRAMMER MANUAL ⎯ 22 ⎯ Examples: *ESE 65 sets the ESER to binary 0100 0001. If the ESER contains the binary value 1000 0010

Strona 5 - 5. COMMANDS AND SYNTAX

GDM-8246 MULTIMETER PROGRAMMER MANUAL ⎯ 24 ⎯ *SRE? Returns: <NR1> is in the range from 0 through 255. Examples *SRE 7 sets bits of the SRER

Strona 6

GDM-8246 MULTIMETER PROGRAMMER MANUAL ⎯ 26 ⎯ Examples: :CONFigure:RANGe? might return 50.000 to indicate the 50V range at DCV. Please refer to th

Strona 7 - I. GPIB message terminators

GDM-8246 MULTIMETER PROGRAMMER MANUAL ⎯ 28 ⎯ DC Current DCA AC Current ACA AC+DC Current AC+DCA ACA + Frequency Hz+ACA Resistance OHM Capacit

Strona 8

GDM-8246 MULTIMETER PROGRAMMER MANUAL ⎯ 30 ⎯ Please refer to the unit for every range shown as Table 6-1. :CONFigure:CURRent:ACDC <NR2> Fu

Strona 9

GDM-8246 MULTIMETER PROGRAMMER MANUAL ⎯ 32 ⎯ :CONFigure: VOLTage:DC 12 sets the DC voltage function and 50V range. Please refer to the unit for e

Strona 10 - PROGRAMMER MANUAL

GDM-8246 MULTIMETER PROGRAMMER MANUAL ⎯ 34 ⎯ :READ?(query only) Function: Returns the value displayed on the primary and secondary display with 1

Strona 11 - *CLS (no query form)

GDM-8246 MULTIMETER PROGRAMMER MANUAL ⎯ 36 ⎯ :CALCulation:LIMit:LOWer? :CALCulation:LIMit:LOWer <NR2> Examples: :CALCulation:LIMit:LOWer? m

Strona 12 - GW_Inc, GDM-8246, FW1.00

GDM-8246 MULTIMETER PROGRAMMER MANUAL ⎯ 2 ⎯ 2. CONNECTING THE DIGITAL MULTIMETER VIA GPIB INTERFACE The GPIB interface capabilities: The GPIB int

Strona 13

GDM-8246 MULTIMETER PROGRAMMER MANUAL ⎯ 38 ⎯ <Boolean> can be o(off) or 1(on). Examples: :CALCulation:MINimum? might return 1 in the MIN

Strona 14 - :CONFigure:MODe?(query only)

GDM-8246 MULTIMETER PROGRAMMER MANUAL ⎯ 40 ⎯ :CALCulation: SDBM:REFerence <NR1> Examples: :CALCulation:SDBM:REFerence? might return 0600 in

Strona 15 - Set the continuity function

GDM-8246 MULTIMETER PROGRAMMER MANUAL ⎯ 42 ⎯ Examples STATus:OPERation:ENABle 32767 sets all 15 bits of the register to 1. If the STATus:OPERatio

Strona 16 - Set the DC diode function

GDM-8246 MULTIMETER PROGRAMMER MANUAL ⎯ 44 ⎯ STATus:QUEStionable:EVENt(query only) Function: Return and clear the contents of the QUEStionable re

Strona 17

GDM-8246 MULTIMETER PROGRAMMER MANUAL ⎯ 46 ⎯ 7. STATUS AND ERROR REPORTING A set of status registers allows the user to quickly determine the

Strona 18 - (query only)

GDM-8246 MULTIMETER PROGRAMMER MANUAL ⎯ 48 ⎯ Figure 8: Status registers and related commands The CONDition register is a read-only registe

Strona 19 - Returns limit result

GDM-8246 MULTIMETER PROGRAMMER MANUAL ⎯ 50 ⎯ Status Registers There are two status registers are included to the DMM defined by IEEE-488.1 and

Strona 20

GDM-8246 MULTIMETER PROGRAMMER MANUAL ⎯ 52 ⎯ z Event Status Enable Register (ESER) z OPERation Enable Register z QUEStionable Enable Registe

Strona 21 - STATus:OPERation:ENABle

GDM-8246 MULTIMETER PROGRAMMER MANUAL ⎯ 54 ⎯

Strona 22 - STATus:QUEStionable:ENABle

GDM-8246 MULTIMETER PROGRAMMER MANUAL ⎯ 4 ⎯ The GPIB connection testing If you want to test whether the GPIB connection is working or not, you ca

Strona 23 - SYSTem:VERSion? (query only)

GDM-8246 MULTIMETER PROGRAMMER MANUAL ⎯ 6 ⎯ z Do not use more than 15m of cable to connect devices to a PC. z Ensure the same baud rate is used

Strona 24 - Status Registers

GDM-8246 MULTIMETER PROGRAMMER MANUAL ⎯ 8 ⎯ The RS232 connection testing If you want to test whether the RS232 connection is working or not, you

Strona 25

GDM-8246 MULTIMETER PROGRAMMER MANUAL ⎯ 10 ⎯ command identifies it as a query. Layer D is interrelated with device information. Different devic

Strona 26

GDM-8246 MULTIMETER PROGRAMMER MANUAL ⎯ 12 ⎯ Table 1 defines the Boolean and other parameter types for the Digital Multimeter. Parameter Type De

Strona 27

GDM-8246 MULTIMETER PROGRAMMER MANUAL ⎯ 14 ⎯ Combining Commands You can use a semicolon (;) to combine commands. But continuously query command w

Strona 28 - ⎯ 54 ⎯

GDM-8246 MULTIMETER PROGRAMMER MANUAL ⎯ 16 ⎯ :CONFigure:SFRequency Sets frequency function. :CONFigure:RESistance <NR2> Sets resistance

Komentarze do niniejszej Instrukcji

Brak uwag